Species Reactivity : Human (Homo sapiens)
UniProt : Q6P1Q0
Abbreviation : LETMD1
Alternative Names : 1110019O13Rik; DKFZp586A011; HCCR-2; HCCR1; cervical cancer 1 protooncogene|reg µLator of TP53
Application : ELISA
Range : 15.6-1000 pg/mL
Sensitivity : 6.5 pg/mL
Intra-AssayCV : ?4.6%
Inter-AssayCV : ?7.5%
Recovery : 0.96
Sample Type : Serum, Plasma, Other biological fluids
Detection Method : Sandwich
Analysis Method?? : Quantitive
Test principle : This assay employs a two-site sandwich ELISA to quantitate LETMD1 in samples. An antibody specific for LETMD1 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyLETMD1 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conj µgated antibody specific for LETMD1 is added to the wells. After washing, Streptavidin conj µgated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of LETMD1 bound in the initial step. The color development is stopped and the intensity of the color is measured.
Product Overview : LETMD1 is involved in tumorigenesis and may function as a negative reg µLator of the TP53/p53. It is found in kidney, liver, skeletal muscle, heart and brain and is over-expressed in various tumors including leukemia, lymphoma, and carcinomas of the breast, kidney, ovary, stomach, colon and uterine cervix. There are six isoforms. HCCR-2 that was overexpressed in various human tumors including leukemia, lymphoma, and carcinomas of the breast, kidney, ovary, stomach, colon, and uterine cervix. Ectopic expression of HCCR-2 res µLted in direct tumorigenic conversions of NIH/3T3 and Rat1 fibroblasts. HCCR-2 probably represents a new oncogene that is related to tumorigenesis, functioning as a negative reg µLator of the p53 tumor suppressor.
Stability : The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. The loss rate was determined by accelerated thermal degradation test. Keep the kit at 37°C for 4 and 7 days, and compare O.D.values of the kit kept at 37°C with that of at recommended temperature. (referring from China Biological Products Standard, which was calc µLated by the Arrhenius equation. For ELISA kit, 4 days storage at 37°C can be considered as 6 months at 2 - 8°C, which means 7 days at 37°C equaling 12 months at 2 - 8°C).